Conducted and over-the-air testing
Conducted testing injects interference directly into the antenna or receiver port — precise, repeatable and ideal for signal-level development work. Over-the-air (OTA) testing radiates interference across the air interface instead, so the antenna sees interference arriving from real directions. The two are complementary: conducted for controlled level work, OTA for spatial behaviour and wavefront effects.
Why direction matters for a CRPA
A controlled reception pattern antenna (CRPA) rejects interference by steering spatial nulls toward each jamming direction. An N-element array can place nulls on up to N−1 directions. A single interference source — whatever its waveform — arrives from one direction and is simply nulled. Exercising the array’s spatial processing therefore needs interference from several directions at once, which is exactly what a multi-node over-the-air setup provides.
AWSG Chamber — multi-node radiated testing
The AWSG Chamber configuration places several battery-powered GNSS-band emitter nodes around the device under test, each controlled wirelessly from a single console. Node placement sets the angles of arrival; the operator sets each node’s waveform profile and output level and arms them together for a synchronised test.
Up to five independent emitter nodes positioned around the DUT create genuine multi-angle interference scenarios across the array.
Non-stationary random, fast wideband sweep, CW tone, linear ramp and adaptive cycling across the GNSS L-band.
One console, five screens, no cables across the chamber — with a synchronised start across every node.
Chamber-based by design
Because the nodes radiate, the AWSG Chamber configuration is intended for use inside a shielded or anechoic chamber, which contains the emissions and keeps operation licence-exempt. It complements conducted AWSG test instruments and established GNSS wavefront and chamber-simulation methods, and is aimed at development and stress-testing rather than replacing formal qualification.